dc.contributor.advisor |
Lingnau, Christel |
|
dc.contributor.advisor |
Machado, Álvaro Muriel Lima |
|
dc.contributor.author |
Silva, Matheus Nunes |
|
dc.date.accessioned |
2013-11-25T12:37:56Z |
|
dc.date.available |
2013-11-25T12:37:56Z |
|
dc.date.issued |
2011-12-16 |
|
dc.identifier.citation |
SILVA, M. N. Aplicação de laser scanner terrestre para determinação de variáveis dendrométricas em Pinus spp. 2011. 130 f. Dissertação (Mestrado em Engenharia Florestal) - Universidade Federal do Paraná, Curitiba. 2011. |
pt_BR |
dc.identifier.uri |
http://www.bibliotecaflorestal.ufv.br/handle/123456789/5238 |
|
dc.description |
Dissertação de Mestrado defendida na Universidade Federal do Paraná |
pt_BR |
dc.description.abstract |
O uso de dados laser scanner terrestre é uma ferramenta importante para coleta de
dados tridimensionais. Esta dissertação teve como objetivo utilizar dados obtidos por
meio de varredura simples e múltipla para a mensuração de árvores validando os
resultados com valores paramétricos e comparar com os resultados de dados
dendrométricos medidos de forma tradicional. A coletada de dados tradicionais, laser
scanner terrestre e paramétricos foi realizada em 12 árvores de Pinus spp.. As
medidas tradicionais foram diâmetros ao longo do fuste medidos com a árvore
derrubada com suta e fita métrica e altura total com hipsômetro Vertex III. As
medidas paramétricas foram a altura total das árvores medidas com trena após a
derrubada, fotografias digitais classificadas de cortes transversais em alturas
especificas e volume determinado por xilômetro das três primeiras toras de um
metro. O processamento de dados laser consistiu na filtragem manual das árvores
para obtenção dos fustes e a criação e programação de algoritmos para
determinação das variáveis dendrométricas. Para obtenção da altura total das
árvores aplicou-se um único método de processamento laser tanto para varreduras
múltiplas como simples. Testaram-se quatro métodos de obtenção de diâmetros pelo
processamento laser (Distância Máxima, Circunferência Ótima, Área Laser e Área
Laser Modificado), sendo que os quatro foram aplicados nas varreduras múltiplas e
três nas varreduras simples totalizando um total de 9 combinações de métodos e
modelos de varredura. Os volumes das três primeiras toras foram determinados pelo
método de Smalian, Huber e Newton e comparados com a cubagem rigorosa por
medidas tradicionais e com o xilômetro. Os resultados indicaram que alguns pontos
da árvore são problemáticos para a filtragem como é o caso da base e das copas. A
ocorrência de vento no momento da aquisição de dados é um fator limitante
principalmente em varreduras múltiplas. As alturas obtidas pelo processamento
laser, utilizando dados de varredura simples ou múltipla, foram superiores aos
obtidos pelo hipsômetro Vertex III. Porém, não existiram diferenças estatísticas
(Tukey α = 0,05) entre os resultados laser, medidas tradicionais e o valor
paramétrico. Para os diâmetros e áreas transversais quando comparados com a
área transversal real apenas um dos métodos laser propostos diferiu
estatisticamente dos resultados das medidas tradicionais e do valor paramétrico.
Conclui-se que a partir da altura onde existe um adensamento de copas tornou-se
inviável a modelagem com o laser. Para os volumes, o método de Huber foi o mais
eficiente para as primeiras toras utilizando dados laser. Os métodos de Newton e
Smalian não são indicados para a volumetria da primeira tora, pois esta sofre muita
influência da filtragem da base das árvores. Estatisticamente, eliminando o método
de Smalian e Newton para a primeira tora, as medidas laser, tradicionais e
paramétricas são iguais pelo teste de Tukey a 5% de significância. Embora em geral
não existam diferenças estatísticas entre varreduras simples e múltiplas em
comparação com medidas tradicionais e paramétricas, os resultados de varredura
múltipla tem menor erro absoluto e menor variância de resultados sendo indicado o
uso principalmente para obtenção de diâmetro e áreas transversais nas partes mais
altas das árvores. |
pt_BR |
dc.description.abstract |
The use of terrestrial laser scanner data is an important tool for collecting threedimensional
data. This paper aims to use data obtained from single and multiple
scan for measuring trees, validating the results with parametric values and
comparing them with traditionally measured data. The data collected from traditional,
parametric and terrestrial laser scanner measuring were taken from 12 Pinus spp.
trees. The traditional measurement were the diameters taken along the stem of
overturned trees by both tape measure and caliper; and the height, taken through a
Vertex III hypsometer. The parametric measures were the total height of the trees,
that were measured by tape after the overthrow; classified digital photographs from
cross-sections taken at determined heights; and their volumes, determined by means
of xylometer from their first three one meter logs. The laser data processing
consisted of a manual filtering in order to obtain the tree stems and the creation and
programming of algorithms for the determination of dendrometric variables. With the
aim to obtain the total height of the trees, it was applied a single laser processing
method for both simple and multiple scans. Four methods were tested to obtain the
diameters by laser processing; the four of them were applied on multiple scans and
three of them on simple scan, comprising a total of nine combinations of methods
and sweeping models. The volumes of the first three logs were determined by the
method of Smalian, Huber and Newton and compared with the scaling obtained by
traditional measurements and xylometer. The results indicated that some points of
the tree are problematic for the filtering, such as the base and the canopy. The
occurrence of winds at the time of data acquisition is a limiting factor, particularly in
multiple scans. The heights obtained by laser scan processing, using data from
single or multiple scan, were better than those obtained by the Vertex III hypsometer.
However, there were no statistical differences (Tukey α = 0,05) between the laser
output, the traditional measurements and the parametric value. For the diameters
and cross-sectional areas, when compared to the real cross-sectional area, only one
of the proposed laser methods differed significantly from the results of the traditional
measurements and the parametric value. We conclude that from the height where
there is a densification of crowns, it became unviable the modeling by means of
terrestrial laser scanner. For the volumes, the Huber method is the most efficient for
the first log data using laser. The methods of Newton and Smalian are not prescribed
for the volumetry of the first log, because it suffers a strong influence from the base
filtering. Statistically, rejecting the Smalian and Newton method for the first log, laser
measurements, traditional and parametric values are equal according to the Tukey
test at 5% significance level. Although in general there are not statistical differences
between single and multiple scans compared to traditional measurements and
parameters, the results of multiple scans presents a lesser absolute error and lesser
variance of results, being indicated mainly for the obtention of the diameters and
cross-section areas of the higher parts of trees. |
pt_BR |
dc.format |
130 folhas |
pt_BR |
dc.language.iso |
pt_BR |
pt_BR |
dc.publisher |
Universidade Federal do Paraná |
pt_BR |
dc.subject.classification |
Ciências Florestais::Manejo florestal::Dendrometria e mensuração florestal |
pt_BR |
dc.subject.classification |
Ciências Florestais::Manejo florestal::Geoprocessamento e sensoriamento remoto |
pt_BR |
dc.title |
Aplicação de laser scanner terrestre para determinação de variáveis dendrométricas em Pinus spp. |
pt_BR |
dc.type |
Dissertação |
pt_BR |