Biblioteca Florestal
Digital

Tratamento de efluente da indústria de celulose através de plasma obtido por eletrólise de alta tensão

Mostrar registro simples

dc.contributor.advisor Reis, César
dc.contributor.author Matias, Alexsandro Antonio
dc.date.accessioned 2014-06-12T14:54:38Z
dc.date.available 2014-06-12T14:54:38Z
dc.date.issued 2010-03-31
dc.identifier.citation MATIAS, A. A. Tratamento de efluente da indústria de celulose através de plasma obtido por eletrólise de alta tensão. 2010. 77 f. Dissertação (Mestrado em Agroquímica ) - Universidade Federal de Viçosa, Viçosa. 2010. pt_BR
dc.identifier.uri http://www.bibliotecaflorestal.ufv.br/handle/123456789/9160
dc.description Dissertação de Mestrado defendida na Universidade Federal de Viçosa pt_BR
dc.description.abstract Os efluentes das fábricas de celulose possuem uma alta carga orgânica e mesmo depois de sujeitos a tratamentos biológicos nas estações de tratamento de efluentes, eles são liberados com um material biorrecalcitrante de difícil degradação no meio hídrico. No presente trabalho, é apresentada uma nova alternativa para o tratamento desses efluentes baseado na produção do radical hidroxila por plasma obtido por eletrólise de alta tensão. Esses radicais possuem alto potencial de oxidação, causando degradação da matéria orgânica. Dois tipos de efluentes da indústria de celulose, um coletado antes do tratamento biológico (EATB) e o outro após o tratamento biológico (EDTB), foram utilizados para avaliar a eficiência do método, que se baseia na aplicação de um diferencial de potencial (580V) entre dois eletrodos mergulhados dentro da solução. Um planejamento unifatorial, tendo o tempo de plasma como variável, foi aplicado em ambos os efluentes. O tempo variou de 30 minutos a 420 minutos, e as respostas foram obtidas pelas análises físico- químicas (DQO, COT, Cor e pH). Os melhores resultados para o efluente EATB foram num tempo de 420 minutos de aplicação de plasma, sendo estes: 99,9% de remoção de DQO, 95,6% de COT, 98,0% de cor e o pH final ficou igual a 11,6. Já para o EDTB, o tempo foi de 360 minutos, e os resultados iguais a 89,9% de DQO, 87,2% de COT, 95,0% de cor e o pH ficou igual a 11,9. Um planejamento fatorial foi realizado na amostra EATB, tendo como fatores temperatura do banho da água de refrigeração da cela, tempo de aplicação do plasma e dióxido de titânio (presença e ausência). O resultado do planejamento fatorial para o EATB mostrou que significativamente a degradação da somente o tempo influenciou matéria orgânica, nas condições estudadas. Estes resultados sugerem que o processo de tratamento de efluente por plasma tem potencial para ser aplicado nas indústrias como substituto ao tratamento biológico, necessitando de correção do valor de pH e do uso complementar de uma resina trocadora de íons para remoção de íons presentes no efluentes, principalmente para a remoção de cloreto. pt_BR
dc.description.abstract Effluents from cellulose processing facilities possess a high organic load and even after being submitted to biological treatment in effluent treatment stations, it is liberated with a biorecalcitrant material which is difficult to break down in the aquatic environment. The present study presents a new alternative for treatment of these effluents, based on production of the hydroxyl radical by plasma obtained by high voltage electrolysis. These radicals have a high oxidation potential, causing degradation of organic material. Two types of industrial cellulose effluents, one collected before biological treatment (EATB) and the other after biological treatment (EDTB), were utilized to evaluated efficiency of the method which is based on application of a voltage difference (580V) between two electrodes submerged in the solution. A unifactorial setup, using plasma time as the variable, was applied to both effluents. Time varied from 30 minutes to 420 minutes, and responses were obtained from physical- chemical analyses (COD, TOC, Color and pH). The best results obtained for the EATB effluent were obtained for 420 minutes of plasma application, being: 99.9% COD removal, 95.6% TOC removal, 95.0% color removal and final pH was equal to 11.9. A factorial setup was utilized for the degradation study of the EATB sample, where the factors were: temperature of the cell cooling water bath, time of plasma application and titanium dioxide (presence or absence). The result of the factorial setup for the EATB showed that only time significantly influenced degradation of the organic material at the studied conditions. These results suggest that the effluent treatment process by plasma has the potential to be applied in industry as a substitute to biological treatment, which requires pH correction and use of a complementary ion exchange resin for removal of ions present in the effluent, principally removal of chloride. pt_BR
dc.format 77 folhas pt_BR
dc.language.iso pt_BR pt_BR
dc.publisher Universidade Federal de Viçosa pt_BR
dc.subject.classification Ciências Florestais::Tecnologia e utilização de produtos florestais::Tecnologia de celulose e papel pt_BR
dc.subject.classification Ciências Florestais::Meio ambiente::Controle ambiental e tratamento de efluentes pt_BR
dc.title Tratamento de efluente da indústria de celulose através de plasma obtido por eletrólise de alta tensão pt_BR
dc.title Treatment of industrial cellulose effluent by plasma obtained by high voltage electrolysis pt_BR
dc.type Dissertação pt_BR

Arquivos deste item

Arquivos Tamanho Formato Visualização
Dissertacao_Alexsandro-Antonio-Matias.pdf 585.1Kb application/pdf Visualizar/Abrir ou Pre-visualizar

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar em toda a Biblioteca


Sobre a Biblioteca Florestal

Navegar

Minha conta